close [x]
close [x]
Price Request

*Add your products to request pricing

Belden Coax - Bundled Miniature

PART #: 7790A

Miniature, 23 AWG solid .023” bare copper conductors, solid copper, gas-injected foam HDPE insulation, Duofoil® + tinned copper braid shield (95% coverage), overall PVC jacket.

Call 1800 00 77 80

Talk to an expert about this product

Coax - Bundled Miniature
Product Configuration

Select from the following options to narrow down to the exact part number for your application:

* Required Fields

Request Pricing

Receive information on pricing and availability

Miniature, 23 AWG solid .023” bare copper conductors, solid copper, gas-injected foam HDPE insulation, Duofoil® + tinned copper braid shield (95% coverage), overall PVC jacket.
Physical Characteristics (Overall)
# Coax6
AWG23
StrandingSolid
Conductor MaterialBC - Bare Copper
Dia. (mm)0.5842
Total Number of Conductors:6
Insulation MaterialGas-injected FHDPE - Foam High Density Polyethylene
Dia. (mm)2.5908
Layer #1
Inner Shield Trade NameDuofoil®
TypeTape
Inner Shield MaterialAluminum Foil-Polyester Tape-Aluminum Foil
Coverage (%)100
Inner Jacket MaterialPVC - Polyvinyl Chloride
Nom. Dia. (mm)4.0386
Number1
ColorRed
Outer Jacket MaterialPVC - Polyvinyl Chloride
Overall Nominal Diametre:15.164 mm
Mechanical Characteristics (Overall)
Operating Temperature Range:-35°C To +75°C
UL Temperature Rating:60°C
Non-UL Temperature Rating:75°C
Bulk Cable Weight:241.088 Kg/Km
Max. Recommended Pulling Tension:960.811 N
Min. Bend Radius/Minor Axis:152.400 mm
Applicable Specifications and Agency Compliance (Overall)
NEC/(UL) Specification:CMR
CEC/C(UL) Specification:CMG
EU Directive 2011/65/EU (ROHS II):Yes
EU CE Mark:Yes
EU Directive 2000/53/EC (ELV):Yes
EU Directive 2002/95/EC (RoHS):Yes
EU RoHS Compliance Date (mm/dd/yyyy):01/01/2004
EU Directive 2002/96/EC (WEEE):Yes
EU Directive 2003/11/EC (BFR):Yes
CA Prop 65 (CJ for Wire & Cable):Yes
MII Order #39 (China RoHS):Yes
RG Type:Mini
UL Flame Test:UL1666 Vertical Shaft
CSA Flame Test:FT4
Suitability - Indoor:Yes
Suitability - Outdoor:Yes
Plenum (Y/N):No
Electrical Characteristics (Overall)
Other Electrical Characteristic 1:Impedance tested in accordance with ASTM D-4566 paragraph 43.2, option 2 using a 75 Ohm fixed bridge and termination.
Other Electrical Characteristic 2:Return Loss Tested in Accordance With ASTM D-4566 Paragraph 45.3, Using a 75 Ohm Fixed Bridge and Termination.
Sweep Testing:Sweep tested 5 MHz to 4.5 GHz.