close [x]
close [x]
Price Request

*Add your products to request pricing

ATEN 30A/32A 24-Outlet Outlet-Metered & Switched eco PDU

PART #: AT-PE8324

30A/32A 24-Outlet Outlet-Metered & Switched eco PDU

Call 1800 00 77 80

Talk to an expert about this product

30A/32A 24-Outlet Outlet-Metered & Switched eco PDU Rollover to zoom [+]

The power status of each outlet can be set individually, allowing users to switch each device On/Off. The eco PDU also offers comprehensive power analysis reports which can separate departments and locations, providing precise measurements of current, voltage, power and watt-hour in a real-time display. Installation and operation is fast and easy: plugging cables into their appropriate ports and user-friendly browser-based configuration and management is all that is entailed. Since the eco PDU firmware is upgradeable over the Net, you can stay current with the latest functionality improvements simply by downloading updates from our website as they become available.

NRGence eco PDU supports any 3rd party V3 SNMP Manager Software and NRGence eco Sensors (eco PDU Manager Software). eco Sensors provides you with an easy method for managing multiple devices, offering an intuitive and user-friendly Graphical User Interface that allows you to configure a PDU device and monitor power status of the equipment connected to it.

With its advanced security features and ease of operation, the eco PDU is the most convenient, most reliable, and most cost effective way to remotely manage power access for multiple computer installations and allocate power resources in the most efficient way possible.
FunctionPE8324APE8324BPE8324G
Electrical
Nominal Input Voltage100 – 120 VAC100 – 240 VAC100 – 240 VAC
Maximum Input Current30A(Max); 24A(UL de-rated)30A Max; 24A (UL de-rated)32A Max
Input Frequency50-60 Hz50-60 Hz50-60 Hz
Input ConnectionNEMA L5-30PNEMA L6-30PIEC 60309 32A
Input Power6240 VA(Max); 4992 VA(UL de-rated)6240 VA(Max); 4992 VA(UL de-rated)7360 VA(Max)
Outlet TypeTotal: 24 x NEMA 5-15R
Bank1-1: Outlet 1 – 8; 8 x NEMA 5-15R
Bank1-2: Outlet 9 – 16; 8 x NEMA 5-15R
Bank2: Outlet 17 – 24; 8 x NEMA 5-15R
Total: 21 x IEC320 C13 + 3 x IEC320 C19
Bank1-1: Outlet 1 – 8; 7 x C13 + 1 x C19
Bank1-2: Outlet 9 – 16; 7 x C13 + 1 x C19
Bank2: Outlet 17 – 24; 7 x C13 + 1 x C19
Total: 21 x IEC320 C13 + 3 x IEC320 C19
Bank1-1: Outlet 1 – 8; 7 x C13 + 1 x C19
Bank1-2: Outlet 9 – 16; 7 x C13 + 1 x C19
Bank2: Outlet 17 – 24; 7 x C13 + 1 x C19
Nominal Output Voltage100 – 120 VAC100 – 240 VAC100 – 240 VAC
Maximum Output Current (Outlet)NEMA 5-15R: 15A(Max); 12A(UL de-rated)C13: 15A(Max); 12A(UL de-rated)
C19: 15A(Max); 12A(UL de-rated)
C13: 10A(Max)
C19: 16A(Max); TUV De-rated 15A(Max)
Maximum Output Current (Bank)15A(Max); 12A(UL de-rated)15A(Max); 12A(UL de-rated)16A(Max); TUV De-rated 15A(Max)
Maximum Output Current (Total)30A(Max); 24A(UL de-rated)30A(Max); 24A(UL de-rated)32A(Max); TUV De-rated 30A(Max)
Breakers2 x 16A UL489 Breaker2 x 16A UL489 Breaker2 x 16A UL489 Breaker
MeteringOutlet Level Current, Voltage, VA, PF, KWh MonitoringOutlet Level Current, Voltage, VA, PF, KWh MonitoringOutlet Level Current, Voltage, VA, PF, KWh Monitoring
Outlet SwitchingYesYesYes
Environment Sensor Ports444
Metering AccuracyVoltage Range: 100VAC ~ 250VAC +/-1%
Power Range: 100W ~ Maximum Capacity +/- 2%
Current Range: 0.1A~1A +/- 0.1A, 1A~20A +/-1%
Voltage Range: 100VAC ~ 250VAC +/-1%
Power Range: 100W ~ Maximum Capacity +/- 2%
Current Range: 0.1A~1A +/- 0.1A, 1A~20A +/-1%
Voltage Range: 100VAC ~ 250VAC +/-1%
Power Range: 100W ~ Maximum Capacity +/- 2%
Current Range: 0.1A~1A +/- 0.1A, 1A~20A +/-1%
Physical Properties
Dimensions (L x W x H)177.50 x 6.60 x 4.40 cm
(69.88 x 2.6 x 1.73 in.)
177.50 x 6.60 x 4.40 cm
(69.88 x 2.6 x 1.73 in.)
177.50 x 6.60 x 4.40 cm
(69.88 x 2.6 x 1.73 in.)
Weight6.33 kg ( 13.94 lb )6.33 kg ( 13.94 lb )6.33 kg ( 13.94 lb )
Power Cord Length1.6 m1.6 m1.6 m
Environmental
Temperature (Operating / Storage)0 – 50°C / -20 – 60°C0 – 50°C / -20 – 60°C0 – 40°C / -20 – 60°C
Humidity (Operating & Storage)0 – 80% RH, Non-Condensing0 – 80% RH, Non-Condensing0 – 80% RH, Non-Condensing
Compliance
EMC VerificationFCC Part 15 Class A, Others by RequestFCC Part 15 Class A, Others by RequestCE, Others by Request
Safety VerificationBy RequestBy RequestCE-LVD, Others by Request