Introduction
Madison Technologies provides tube bundle assemblies in Direct Install (DI), Direct Bury (DBT) and Low Fire hazard (LFH).
System Features
-
Flexibility - When wrapped around a 10d mandrel (where d = tube diameter) there is no kinking or damage and an appropriate diameter ball passes completely through the microduct.
-
Pressure - Micro duct withstands 17 bar air pressure underwater for 2 hours without leaks.
-
Friction - Low friction lining material used to increase fibre blow distance.
-
Crush - After a 1000N load (used on Polyethylene microducts) and 400N load (used on Low Fire Hazard mirco ducts) for 1minute, the residual deformation of the microduct does not exceed 15% measured within 1 minute of unloading.
Features
Direct Burial Microducts (DBT)
Assembly of 5mm PE Tubes, each with low friction performance. The Tube bundle is surrounded by a 150 micron aluminium moister barrier layer bonded inside an inner sheath of MDPE. Over the sheath is a layer of Nylon to provide Termite Resistance & mechanical strength with a final outer layer of HDPE. Non-Metallic versions are also available on request.
Ordering Information6185 - Microduct: DBT19, 19-tube bundle, 32.2mm Overall Diameter 6569 - Microduct: DBT24, 24-tube bundle, 37.8mm Overall Diameter 6570 - Microduct: DBT7, 7-tube bundle, 22.2mm Overall Diameter 6571 - Microduct: DBT2, 2-tube bundle, 17.2x12.2mm Overall Diameter 6629 - Microduct: DBT1, 1-tube bundle, 12.2mm Overall Diameter 6664 - Microduct: DBT4, 4-tube bundle, 19.3mm Overall Diameter On Request - Microduct: DBT12, 12-tube bundle, 28.2mm Overall Diameter
|
|